Thứ Sáu, 14 tháng 2, 2014

EtherCAT coupler - EK1100 - Beckhoff Vietnam

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7

EtherCAT coupler EK1100 Beckhoff Vietnam
8 chanel digital input terminal 24VDC EL1008 Beckhoff Vietnam
Potential distributor terminal <60V, +24 EL9186 Beckhoff Vietnam
Potential distributor terminal <60V, 0VDC EL9187 Beckhoff Vietnam
Potential supply terminal <60V, <10A EL9100 Beckhoff Vietnam
8 chanel digital output terminal 24VDC, 2A EL2024 Beckhoff Vietnam
Analog output terminal 2 chanel  -10V….10V,12Bit EL4032 Beckhoff Vietnam
Bus end cover EL9011 Beckhoff Vietnam
2 port etherCAT junction EK1122 Beckhoff Vietnam
Battery pack for 24-V-Supply C9900-U330 Beckhoff Vietnam
Analog input terminal 0….10V, 16 Bit EL3162 Beckhoff Vietnam
Power supply terminal EL9410 Beckhoff Vietnam
PROFIBUS-Master EtherCAT- Terminal EL6731 Beckhoff Vietnam
FL Switch SFNB 5TX 2891001 Beckhoff Vietnam
Power supply unit terminal  0-10VDC EL9510 Beckhoff Vietnam
Analog output terminal  chanel -10V…..10V, 12Bit EL4034 Beckhoff Vietnam
8 chanel digital output terminal 24VDC, 0.5A EL2008 Beckhoff Vietnam
PROFIBUS-Master EtherCAT-Terminal EL6731-0010 Beckhoff Vietnam
Elektronic terminal DC-DC converter 24VDC-10VDC 859-802 Beckhoff Vietnam
Memory terminal 128 kByte EL6080 Beckhoff Vietnam
UPS intergrated in the 24V supply C9900-U209 Beckhoff Vietnam

Thứ Ba, 11 tháng 2, 2014

EA2-TX-100-HD | Michell Vietnam | Easidew Transmitter

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7
EA2-TX-100-WX | B393-040 | Easidew Transmiter Michell | Michell Vietnam
Easidew B393-040 Dewpoint
Performance
Measurement Range-100 to +20°Cdp
Accuracy±2°Cdp
Response Time5 mins to T95 (dry to wet)
Repeatability0.5°Cdp
CalibrationTraceable 13 point calibration
Electrical Specifications
Output Signal4-20 mA (2-wire connection, current source)
User-configurable over range
OutputDew point, moisture content in ppmV
Analog Output Scaled RangeDew point: -100 to +20°C
Moisture content in gas: 0-3000ppmV
Non-standard available upon request
Supply Voltage12 to 28 V DC
Load ResistanceMax 250 Ω @ 12 V (500 Ω @ 24 V)
500 Ω @ 24 V
Current Consumption20 mA max
CE MarkedCertified
Operating Specifications
Operating Temperature-40 to + +60°C
Operating Pressure45MPa (450 barg/6500 psig) max
Overpressure Ratingx2 operating pressure 90 MPa (900 barg)
Flow Rate1 to 5 Nl/min mounted in standard sampling block;
0 to 10m/sec direct insertion insertion
Temperature CoefficientTemperature compensated across operating temperature range
Mechanical specifications
Ingress ProtectionIP66 in accordance with standard BS EN 60529:1992
NEMA 4 in protection accordance with standard NEMA 250-2003
Housing Material316 stainless steel
DimensionsL=132mm x ø45mm (with connector)
Filter
(Sensor Protection)
Standard: HDPE guard <10µm
Optional:  316 stainless steel sintered guard <80µm
Process Connection and Material5/8" - 18 UNF
316 stainless steel
Weight150g
InterchangeabilityFully interchangeable transmitter
Electrical ConnectionsHirschmann GDS series (DIN 4350-C)
Diagnostic Conditions
(Factory Programmed)
Condition
Sensor fault
Under-range dew point
Over-range dew point
Output23 mA4 mA20 mA