Thứ Ba, 11 tháng 2, 2014

EA2-TX-100-HD | Michell Vietnam | Easidew Transmitter

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
        0162.999.888.7
EA2-TX-100-WX | B393-040 | Easidew Transmiter Michell | Michell Vietnam
Easidew B393-040 Dewpoint
Performance
Measurement Range-100 to +20°Cdp
Accuracy±2°Cdp
Response Time5 mins to T95 (dry to wet)
Repeatability0.5°Cdp
CalibrationTraceable 13 point calibration
Electrical Specifications
Output Signal4-20 mA (2-wire connection, current source)
User-configurable over range
OutputDew point, moisture content in ppmV
Analog Output Scaled RangeDew point: -100 to +20°C
Moisture content in gas: 0-3000ppmV
Non-standard available upon request
Supply Voltage12 to 28 V DC
Load ResistanceMax 250 Ω @ 12 V (500 Ω @ 24 V)
500 Ω @ 24 V
Current Consumption20 mA max
CE MarkedCertified
Operating Specifications
Operating Temperature-40 to + +60°C
Operating Pressure45MPa (450 barg/6500 psig) max
Overpressure Ratingx2 operating pressure 90 MPa (900 barg)
Flow Rate1 to 5 Nl/min mounted in standard sampling block;
0 to 10m/sec direct insertion insertion
Temperature CoefficientTemperature compensated across operating temperature range
Mechanical specifications
Ingress ProtectionIP66 in accordance with standard BS EN 60529:1992
NEMA 4 in protection accordance with standard NEMA 250-2003
Housing Material316 stainless steel
DimensionsL=132mm x ø45mm (with connector)
Filter
(Sensor Protection)
Standard: HDPE guard <10µm
Optional:  316 stainless steel sintered guard <80µm
Process Connection and Material5/8" - 18 UNF
316 stainless steel
Weight150g
InterchangeabilityFully interchangeable transmitter
Electrical ConnectionsHirschmann GDS series (DIN 4350-C)
Diagnostic Conditions
(Factory Programmed)
Condition
Sensor fault
Under-range dew point
Over-range dew point
Output23 mA4 mA20 mA