Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh
Tell : 0915.980.479
0162.999.888.7
Email : vinhmv.pitesco@gmail.com
Website: www.pitesvietnam.com
www.sensor-encoder.com
COUNTIS, DIRIS & MEASURING DEVICES
ENERGY METERS & PULSE CONCENTRATOR
• For single phases LV network • Direct input up to 32 A 1 fixed 100 Wh impulse output • 1 module • IEC 62053-21 class 1
|
|
|
|
• For single phase LV network • Direct connection up to 63 A • +kWh metering • Active power measurement • 1 impulse output • MID version • Dual tariff version
|
|
|
|
• For three phases LV network • Direct connection up to 63 A • +kWh metering • Activ power measurement • 1 impulse output • Dual tariif version
|
|
|
|
• For three phases LV network • Direct connection up to 100 A • +kWh and + kvarh metering • Activ power measurement • 1 impulse output or JBUS/MODBUS RS485 serial port • MID version • Dual tariff version
|
|
|
|
• For three phases LV network • Connection up to 6000A via current transformer • +kWh and + kvarh metering • Active and reactive power measurement • 1 impulse output or JBUS/MODBUS RS485 serial port
• MID Version • Dual tariff version
|
|
|
|
• For three phases LV network • Connection up to 6000A via current transformer • +kWh and + kvarh metering • Active and reactive power measurement • Voltage, current and power factor measurement • 1 impulse output or JBUS/MODBUS RS485 serial port • Multi tariff
|
|
|
|
MULTI-FUNCTION METER
• For LV network • Multi-measurements (3U, 3V, 3I, In, ΣP, ΣQ, ΣS, ΣFP and F) • Max. 4I and ΣP • +kWh and + kvarh metering • THD 3U, 3V and 3I integrated up to row 51 • 1 impulse, alarm or command output • Version with JBUS/MODBUS RS485 serial port • Internal temperature sensor
|
|
|
|
• For LV network • Multi-measurements (3U, 3V, 3I, In, ΣP, ΣQ, ΣS, ΣFP and F) • Max. 4I and ΣP • +kWh and + kvarh metering • THD 3U, 3V and 3I integrated up to row 51 • Optional modules: - 1 impulse output JBUS/MODBUS RS485 serial port
|
|
|
|
• For LV and HV network • Multi-measurements (3U, 3V, 3I, In, +/-3P, +/-ΣP, +/-3Q, +/-ΣQ, ΣS, 3FP, ΣFP and F) • Max. demand and last demand 4I, +/-ΣP, +/-ΣQ and ΣS • kWh (+/-), kvarh (+/-) and kVAh metering • Programmable time meter • THD 3U, 3V, 3I and In integrated up to harmonic number 51 Optional modules: • Optional modules - Ethernet module - Ethernet module with gateway - Temperature module - 2 impulse output - harmonics analysis on 3U, 3V, 3I and In for harmonics 3 to 25 - 2 to 6 input / output for control/command or monitoring - 2 to 4 analog output - JBUS/MODBUS RS485 or Profibus DP serial port - storing of P+/P-/Q+/Q- average values over 31 or 62 days - storing of10 last voltage C18 over voltage and voltage cut-off (EN50160)
|
|
|
|
• Neutral current measurement using a 4th CT • For LV and HV network • Multi-measurements (3U, 3V, 3I, In, +/-3P, +/-ΣP, +/-3Q, +/-ΣQ, ΣS, 3FP, ΣFP and F) • Max. demand and last demand 4I, +/-ΣP, +/-ΣQ and ΣS, • kWh (+/-), kvarh (+/-) and kVAh metering • Programmable time meter • THD 3U, 3V, 3I and In integrated up to harmonic number 51 • Optional modules: 2 impulse output harmonics analysis on 3U, 3V, 3I and In for harmonics 3 to 25 2 to 6 input / output for control/command or monitoring - 2 to 4 analog output JBUS/MODBUS RS485 or Profibus DP serial port storing of P+/P-C42/Q+/Q- average values over 31 or 62 days storing of10 last voltage over voltage and voltage cut-off (EN50160)
|
|
|
|
Same functions DIRIS A40 + • Mean power load curves (P,Q,S) • Overvoltage, voltage through and outage detection • Overcurrent detection • Saving of RMS 1/2 périod curves link to events • Tangent Phi • Voltage and current unbalance
|
|
|
|
The DIRIS A80 offers the following functions: • The monitoring of fault currents (Residual Current Monitoring) • Multi-measurement (current, voltage, frequency, power…) • Energy metering
|
|
|
|
• For LV network • Energy measurement for your existing installations • Combination of COUNTIS E meters and TCO split-core current transformers • Combination of DIRIS A multi-measurement stations and TCO split-core current transformers • Easy installation • Guaranted connection
|
|
|
|
ANALYSIS
Network analysor
• Acquisition, procession and memory of measures, harmonics, alarms, load curves, load outages, voltages surges and vector diagram
• Ethernet communication
• RS485 link
•USB ports
|
| |
|
COMMUNICATION
• RS232/RS485 • USB/RS485 • Modem / RS232 - RS485 • Repeater RS485 • Ethernet / RS232-RS485
|
| |
|
MEASURING DEVICES
• From 1 to 6000 A • All types of bar and cable passages • Three-phase transformer, opening
|
|
|
|
• DIN version • ECO Version • From 1 to 6000 A • Secondary 100mV (60 or 150 mV available on request
|
|
|
|
• Switch ammeters, voltmeters
• Contact ammeters, voltmeters
• Recorders…
|
|
|
|
METERS & TRANSDUCERS
• Modular boxes for mounting ROTEX or DIN • Dimensions 48 / 72 / 96 / 144
|
|
|
|
• Modular boxes for mounting ROTEX or DIN • Dimensions 48 / 72 / 96 / 144
|
|
|
|
• Modular boxes for mounting ROTEX or DIN • Dimensions 48 / 72 / 96 / 144
|
|
|
|
• Modular boxes for mounting ROTEX or DIN • Dimensions 48 / 72 / 96 / 144
|
|
|
|
• Modular boxes for mounting ROTEX or DIN
• Dimensions 48 / 72 / 96 / 144
|
|
|
|
• Modular boxes for mounting ROTEX or DIN • Dimensions 48 / 72 / 96 / 144
|
|
|
|
• Modular boxes for mounting ROTEX or DIN • Dimensions 48 / 72 / 96 / 144
|
|
|
|
• Embedded or modular boxes • Mono and/or multi-display and programmable
|
|
|
|
• Parameters U, I, F, P, Q, PF and other values • Exists with two types of switch casing: Transducers in surface-mounted switch casings Transducers in modular switch casings
|
|
|
|
• Electromechanical • Electronic
|
|
|
|
• For ammeters, voltmeters... • Centrally mounted or screw mounted
|
|
|
|
Không có nhận xét nào: