Servomex Vietnam SERVOTOUGH FluegasExact 

  
SERVOTOUGH FluegasExact Comb. Analyser 
  
02700D1 
  
CONTROLLER TYPE 
  
GENSafe Area
EU2Haz. Area ATEX Cat 3
EX2Haz. Area IEC Ex Zone 2
NA2N. American CL 1 DIV 2
  
SENSOR HEAD TYPE 
GENSafe Area
EU2Haz. Area ATEX Cat 3
EX2Haz. Area IEC Ex Zone 2
  
MINI PURGE 
 Not Required
 MiniPurge ATEX Cat 3 / IEC Ex Zone 2
 Supplied by others
  
MEASUREMENT 
 Oxygen Only
 Oxygen Only, pcb Enhanced Environmental Protection
 Combustibles Only
 Combustibles Only, pcb Enhanced Environmental Protection
 Oxygen & Combustibles
 Oxygen & Combustibles, pcb Enhanced Environmental Protection
  
COMBUSTIBLES SENSORHigh Sensitivity
 Sulphur Resistant
  
FLOW ALARM 
 Not Required
 Safe Area
 Haz. Area ATEX Cat 3
 Haz. Area IEC Ex Zone 2
 N. American CL 1 DIV 2
  
SUPPLY VOLTAGE 
 110V ac
 240V ac
  
SAMPLE PROBES 
 None
 0.5m SS sample probe, unsupported, open ended, <700°C/1292°F
 1.0m SS sample probe, unsupported, open ended, <700°C/1292°F
 1.5m, SS sample probe, unsupported, open ended, <700°C/1292°F (Vertical Mount Only)
 0.5m SS sample probe, unsupported, filtered, <700°C/1292°F
 1.0m SS sample probe, unsupported, filtered, <700°C/1292°F
 1.5m, SS sample probe, unsupported, filtered, <700°C/1292°F (Vertical Mount Only)
 0.5m SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
 1.0m SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
 1.5m SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
 2.0m SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
 2.5m, SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
 3.0m, SS sample probe, supported, filtered, with shroud,  <700°C/1292°F
 0.5m High Temperature Alloy, sample probe, unsupported, open ended, <1000°C/1832°F
 1.0m High Temperature Alloy, sample probe, unsupported, open ended, <1000°C/1832°F
 1.5m, High Temperature Alloy, sample probe, unsupported, open ended, <800°C/1472°F  (Vertical Mount Only)
 2.0m, High Temperature Alloy, sample probe, unsupported, open ended, <700°C/1292°F  (Vertical Mount Only)
 0.5m High Temperature Alloy, sample probe, unsupported, filtered, <1000°C/1832°F
 1.0m High Temperature Alloy, sample probe, unsupported, filtered, <1000°C/1832°F
 1.5m High Temperature Alloy, sample probe, unsupported, filtered (Vertical Mount Only)
 2.0m High Temperature Alloy, sample probe, unsupported, filtered (Vertical Mount Only)
 0.6m, Ceramic, sample probe, unsupported, filtered, <1500°C/2732°F **Special - Consult Servomex
 1.1m, Ceramic, sample probe, unsupported, filtered, <1500°C/2732°F **Special - Consult Servomex
 0.5m Ceramic, sample probe, open ended, <1750°C/3182°F
 1.0m Ceramic, sample probe, open ended, <1750°C/3182°F
 1.5m Ceramic, sample probe, open ended, <1750°C/3182°F (Vertical Mount Only)
 0.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
 1.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
 1.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
 2.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
 2.5m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
 3.0m, SS sample probe, supported, dual filtered, with shroud, <700°C/1292°F
 0.5m, Hastelloy, sample probe, unsupported, open
 1.0m, Hastelloy, sample probe, unsupported, open
 1.5m, Hastelloy, sample probe, unsupported, open (Vertical Mount Only)
 Non Standard sample probe - refer to Servomex
  
INTERNAL FILTER 5um 
 Fitted
  
INTERNAL FLAME ARRESTORS 
 Fitted
  
  
  
ELECTRICAL CONDUIT ENTRIES 
 3/4"NPT (O2 and COe)
 M20 (O2 or COe)
 M25 (O2 and COe)
 PG13.5 (O2 or COe)
 PG21 (O2 and COe)
  
SENSOR HEAD ENCLOSURE OPTION 
 Breather Fittings
 Corrosive Purge Fittings
 Hazardous Area Purge Fittings
 Special Sensor Head Purge O2 Only - contact Servomex
 Special Sensor Head Purge Dual - contact Servomex
  
SENSOR HEAD MOUNTING OPTION 
 Standard (4"ANSI 150lbs)
 Probe Retention (excluding supported probes)
 Thermal Spacer (excluding supported probes)
 Probe Retention & Thermal Spacer (excluding supported probes)
 High Temperature Stand Off (excluding supported probes)
 High Temperature Stand Off & Probe Retention (excluding supported probes)
  
  
SENSOR HEAD ADAPTOR FLANGE OPTION 
 No Adaption (4"ANSI 150lbs)
 3" ANSI 150lbs equivalent
 DIN 65 equivalent
 DIN 80 equivalent
 JIS 65 equivalent
 JIS 80 equivalent
 Weld -On flange complete with studs (4" ANSI 150lbs equivalent)
 Model 700B/N to 2700 adaptor flange (excluding High Temperature Stand Off)
 Thermox to 2700 adaptor flange (excluding Supported Probes)
  
CONTROL UNIT MOUNTING 
 Wall Mounted
  
CONTROL UNIT ENCLOSURE OPTIONS 
 Blanking Plugs Only
 Breather Port
 Corrosive Purge Fittings
  
UTILITIES UNITS - SAFE 
 None
 Air Set (Oxygen Only)
 Air Set with Autocalibration (Single sensor)
 Air Set with Autocalibration (Dual sensor)
 Air Set with Blowback and Autocalibration (Single sensor)
 Air Set with Blowback and Autocalibration (Dual sensor)
 Air Set and Manual Calibration (Single & Dual sensor)
  
  
  
  
USER MANUALS 
 English
 French (currently undergoing translation) - Please consult Servomex
 German (currently undergoing translation) - Please consult Servomex
  
SERVICE MANUAL 
 None
 English
  
DEFAULT SOFTWARE INTERFACE LANGUAGE 
 English
 French
 German
  
  
  
  
2930A SERVOTOUGH LaserSP 
  
02930A1SERVOTOUGH LaserSP
CONFIGURATION 
 Single Path
AREA CLASSIFICATION 
 Safe Area
 ATEX  and IECEx Cat 3 Gas (Zone 2) Cat 2 Dust (Zone 21)
 ATEX Cat. 2G (Zone 1)
 CSA general purpose
 CSA Class 1, Division 2
MEASUREMENT 
Single Path monitorsMeasurement
  
 CO SERVOTOUGH LaserSP Monitor (carbon monoxide)
 CO SERVOTOUGH LaserSP Monitor, low level detection limit 0.3ppm (carbon monoxide)
 CO2 SERVOTOUGH LaserSP Monitor (carbon dioxide)
 CO2 SERVOTOUGH LaserSP Monitor<400ppm (carbon dioxide)
 NH3 SERVOTOUGH LaserSP Monitor (ammonia)
 HF SERVOTOUGH LaserSP Monitor (hydrogen fluoride)
 HCl SERVOTOUGH LaserSP Monitor (hydrogen chloride)
 H2O SERVOTOUGH LaserSP Monitor 50ppm (water)
 H2S SERVOTOUGH LaserSP Monitor (hydrogen sulphide)
 CH4 SERVOTOUGH LaserSP Monitor (methane)
 HCN SERVOTOUGH LaserSP Monitor (hydrogen cyanide)
 C3H6 SERVOTOUGH LaserSP Monitor (propylene)
 C2H4O SERVOTOUGH LaserSP Monitor (ethylene oxide)
 CH2O SERVOTOUGH LaserSP Monitor (formaldehyde)
 C2H2 SERVOTOUGH LaserSP Monitor (acetylene)
 CH3I SERVOTOUGH LaserSP Monitor (methyl iodide)
 N2O SERVOTOUGH LaserSP Monitor (nitrous oxide)
 N2O SERVOTOUGH LaserSP Monitor (ppm nitrous oxide)
  
MEASURING RANGE 
 Please state
MEASUREMENT UNITS 
 mg/m3
 ppm
 % vol
  
DUAL MEASUREMENT 
 Not Required
 H2O dual gas add-on as second gas (for HF, HCl, NH3 and CO) Note: For CO only for Temp below 200C or above 700C
 Dual gas add-on CH4 option as second gas
 Dual gas, add on CO2 as second gas (for CO)
 Dual gas, add on temperature (for O2 and CO)
  
DUAL MEASURING RANGE 
 Please state
  
DUAL MEASUREMENT UNITS 
 mg/m3
 ppm
 % vol
 Celsius
  
  
 Gas Component 1
 Stream Comp 1 Normal Range
 Stream Comp 1 Low Range
 Stream Comp 1 High Range
 Process Dust (mg/m3)
 Process Flow (m3/h)
 Process Velocity (m/sec)
 Process Opacity (%)
 Stream Temperature (°C)
 Ambient Temperature (°C)
  
 Trans/Rec Cable 10m (5m supplied as standard)
 Trans/Rec Cable 15m (5m supplied as standard)
 Trans/Rec Cable 20m (5m supplied as standard)
 TU/RU Connecting Cable 5-20m (per metre). 5m supplied as standard.
  
 TU Optical Path Length L1 (mm)
 Stack Diameter L2 (mm)
 RU Optical Path Length L3 (mm)
  
PROCESS PRESSURE UNITS 
 mbar
 bar
PROCESS PRESSURE (bar) 
 Please specify
OPTICAL WINDOW PURGING 
 None (low dust)
 Instrument Air
 Fan
  
  
 N2 (low level O2)
 Steam
SUPPLY VOLTAGE 
 110Vac 50/60Hz
 220Vac 50/60Hz
 24Vdc
HIGH TEMPERATURE APPLICATIONS 
 High temp. O2/CO2/CO applications(>700C) RU Filter mounted/tested
 13606 High Temp O2 with Air Purge (>500C)
  
MOUNTING FLANGE 
 DN50/PN10 (SP Standard)
 DN80/PN10, pair
 ANSI 2"/150lbs, pair
 ANSI 3"/300lbs, pair
 ANSI 4" 150/300lbs, pair
 Other (Specify)
  
SPECIAL FLANGE O-RINGS21031 DN50 Flange 0-ring, 65.0x10.0, PTFE (Teflon)  Max 250C
 21033 DN50 Flange 0-ring, 65.0x10.0, FKM (Viton)  Max 200C
 21034 DN80 Flange 0-ring, 95.0x10.0, FKM (Viton)  Max 200C
TU MOUNTING 
 Indoor
 Outdoor
  
CALIBRATION CELL 
 Stainless Steel (316) For corrosive gases (except HF)
 Stainless Steel (316) For corrosive gases (except HF) electropolished
 Cal cell for O2 (Al) For non-corrosive gases
 Cal cell for HF (AI/PTFE)
MEASUREMENT CELL 
 Order measurement cell as separate item: See 02930964 measurement price list below.
TRANSMISSION OUTPUT 
 Additional 4-20mA for Trans o/p
 Auxiliary board including one 4-20mA
 Second and third 4-20mA analogue output (13474 is required for this option)
ETHERNET OUTPUT 
 Ethernet Connection (without cable)
  
ADDITIONAL NETWORK CABLE 
 Network Cable 15m (including connectors) straight
 Network Cable 15m (including connectors)cross-over
TU/RU PURGING 
 None (Blanked)
 N2 Fittings (Low Level O2)
  
2nd PURGE PORT FITTING 
 Option for 2 purge fitting on each purge/alignment unit
HIGH PRESSURE WINDOW >5 BAR 
 High Pressure Window for O2 HP O2 measurement
  
ALIGNMENT TOOLS 
 Alignment jig w/target
 IR Card (not suitable for HCl, NO, Low conc CO, CO2)
  
PURGE GAS FILTRATION 
 Purge Gas Filter Unit
  
INTEGRATED SPAN CHECK 
 Span check (for non corrosive gases only) incl. switch box.  Check application feasability with Technical Centre before quoting.
 Fixed internal sealed cell (Laser tracking typically for "zero" type applications) Check application feasability with
Technical Centre before quoting.
 Span check with internal sealed cell. Check application feasability with Technical Centre before quoting.
  
2 YEARS SPARES KIT 
 2 years spares kit
  
CERTIFICATE OF ORIGIN 
 Certificate of origin (May be required for FAT by customer)