04416A1SERVOPRO NanoChrome He Background
 includes report software, packaging
Impurities options 
N2 Range 0-250ppb LDL 0.3ppbINJ with 1 valves
Ar Range 0-250ppb LDL 0.5ppbINJ/HC with 2 valves
H2 Range 0-250ppb LDL 0.5ppbINJ with 1 valves
N2/H2 Range 0-250ppb LDL 0.5ppbINJ with 1 valves
CO Range 0-250ppb LDL 0.5ppbINJ with 1 valves
CO2 Range 0-250ppb LDL 0.5ppbBF/HC with 2 valves
CH4 Range 0-250ppb LDL 0.5ppbBF/HC with 2 valves
CO2/CH4 Range 0-250ppb LDL 0.5ppbBF/HC with 2 valves
CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppbBF/HC/SEL with 3 valves
  
Chassis options 
Master ChassisMax. 2 channels with 4 valves
PC+ Slave chassis2 BF/HC channels
Master +Slave1 ChassisMax. 4 channels with 8 valves
  
Carrier GasHelium
  
  
Power115 VAC, 50-60 Hz
 220 VAC, 50-60 Hz
  
Gas Connectors (to match accessories fittings)1/8" VCR
  
Serial portRS-232
  
  
Remote SupportVNC
 Net Support
  
Internal Dilution SystemNot Required ( > 1ppm)
 Required ( One per Chassis)
  
  
  
  
  
SERVOPRO PureGasGas Purifier
  
02005A1_01SERVOPRO PUREGAS, 1/8" COMP, 110V
02005A1_02SERVOPRO PUREGAS, 1/8" COMP, 220V EU
02005A1_03SERVOPRO PUREGAS, 1/8" COMP, 220V UK
02005A1_04SERVOPRO PUREGAS, 1/8" VCR, 110V
02005A1_05SERVOPRO PUREGAS, 1/8" VCR, 220V EU
02005A1_06SERVOPRO PUREGAS, 1/8" VCR, 220V UK
  
  
SpectraScan Analyser 
  
02400A1SpectraScan Analyser
  
Components1 to 3 Components
 4 to 6 Components
 7 to 8 Components
  
04404A1Nitrogen Purity Analyser Base
 includes report software, SS liners, packaging
  
Trace (>10 ppm), Pack 1O2 Impurity - Enter range & LDL
 0-10ppm ≤O2 range ≤ 0-100ppm  LDL is 1.5% full scale
 H2 Impurity - Enter range & LDL
 0-10ppm ≤H2 range ≤ 0-100ppm  LDL is 1.5% full scale
 CH4 Impurity - Enter range & LDL
 0-10ppm ≤CH4 range ≤ 0-100ppm  LDL is 1.5% full scale
  
Trace (>10 ppm), Pack 2Same as Pack 1 +
 Ar Impurity - Enter range & LDL
 0-10ppm ≤Ar range ≤ 0-100ppm  LDL is 1.5% full scale
  
Trace (>10 ppm), Pack 3Same as Pack 2 +
 CO Impurity - Enter range & LDL
 0-10ppm ≤CO range ≤ 0-100ppm  LDL is 1.5% full scale
  
Trace (>10 ppm), Pack 4Same as Pack 3 +
 CO2 Impurity - Enter range & LDL
 0-10ppm ≤CO2 range ≤ 0-100ppm  LDL is 1.5% full scale
  
Trace Exact (<10 ppm), Pack 1O2 Impurity - Enter range & LDL
 0-1ppm ≤O2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Min Range 0-1 ppmH2 Impurity - Enter range & LDL
 0-1ppm ≤H2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
 CH4 Impurity - Enter range & LDL
 0-1ppm ≤CH4 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  
Trace Exact (<10 ppm), Pack 2Same as Pack 1 +
 Ar Impurity - Enter range & LDL
Min Range 0-1 ppm0-1ppm ≤Ar range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  
Trace Exact (<10 ppm), Pack 3Same as Pack 2 +
 CO Impurity - Enter range & LDL
Min Range 0-1 ppm0-1ppm ≤CO range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  
Trace Exact (<10 ppm), Pack 4Same as Pack 3 +
 CO2 Impurity - Enter range & LDL
Min Range 0-1 ppm0-1ppm ≤CO2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  
  
Carrier GasArgon
 Helium (if Argon impurity)
  
Power115 VAC, 50-60 Hz
 220 VAC, 50-60 Hz
  
Gas Connectors (to match accessories fittings)1/8" Swagelok
 1/8" VCR (if 0-1 ppm range)
  
Serial portNot Required
 RS-232
  
Remote SupportVNC
 Net Support
  
Dual Inlets (sample + span, with switching)Not Required
 Required
  
Calibration using background gasNot required
 Required
  
  
  
04405A1Oxygen Purity Analyser Base
 includes report software, SS liners, packaging
  
ASU Process (>10 ppm), Pack 1CH4 Impurity - Enter range & LDL
 0-10ppm ≤CH4 range ≤ 0-500ppm  LDL is 1.5% full scale
 NMHC Impurity - Enter range & LDL
 0-5ppm ≤CH4 range ≤ 0-200ppm  LDL is 1.5% full scale Min.100ppb
  
Trace (>10 ppm), Pack 1N2 Impurity - Enter range & LDL
 0-10ppm ≤N2 range ≤ 0-100ppm  LDL is 1.5% full scale
 (with O2 trap in aux oven)
  
Trace (>10 ppm), Pack 2Same as Pack 1 +
 H2 Impurity - Enter range & LDL
 0-10ppm ≤H2 range ≤ 0-100ppm  LDL is 1.5% full scale
 CH4 Impurity - Enter range & LDL
 0-10ppm ≤CH4 range ≤ 0-100ppm  LDL is 1.5% full scale
  
Trace (>10 ppm), Pack 3Same as Pack 2 +
 CO2 Impurity - Enter range & LDL
 0-10ppm ≤CO2 range ≤ 0-100ppm  LDL is 1.5% full scale
  
Trace (>10 ppm), Pack 4Same as Pack 3 +
 CO Impurity - Enter range & LDL
 0-10ppm ≤CO range ≤ 0-100ppm  LDL is 1.5% full scale
  
Trace (>10 ppm), Pack 5Same as Pack 4 +
 Ar Impurity - Enter range & LDL
 0-10ppm ≤Ar range ≤ 0-100ppm  LDL is 1.5% full scale
  
Trace Exact (<10 ppm), Pack 1N2 Impurity - Enter range & LDL
 0-1ppm ≤N2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
Min Range 0-1 ppm(with O2 trap in aux oven)
  
Trace Exact (<10 ppm), Pack 2Same as Pack 1 +
Min Range 0-1 ppmH2 Impurity - Enter range & LDL
 0-1ppm ≤H2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
 CH4 Impurity - Enter range & LDL
 0-1ppm ≤CH4 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  
Trace Exact (<10 ppm), Pack 3Same as Pack 2 +
 CO2 Impurity - Enter range & LDL
Min Range 0-1 ppm0-1ppm ≤CO2 range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  
Trace Exact (<10 ppm), Pack 4Same as Pack 3 +
 CO Impurity - Enter range & LDL
Min Range 0-1 ppm0-1ppm ≤CO range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  
Trace Exact (<10 ppm), Pack 5Same as Pack 4 +
 Ar Impurity - Enter range & LDL
Min Range 0-1 ppm0-1ppm ≤Ar range < 0-10ppm  LDL is 1.5% full scale,Min.50ppb
  
Carrier GasArgon
 Helium (if Argon impurity measured)
  
Power115 VAC, 50-60 Hz
 220 VAC, 50-60 Hz
  
Gas Connectors (to match accessories fittings)1/8" Swagelok
 1/8" VCR (if 0-1 ppm range)
  
Serial portNot Required
 RS-232
  
Remote SupportVNC
 Net Support
  
Dual Inlets (sample + span, with switching)Not Required
 Required
  
Calibration using background gasNot required
 Required