| 04416A1 | SERVOPRO NanoChrome He Background |
| | includes report software, packaging |
| Impurities options | |
| N2 Range 0-250ppb LDL 0.3ppb | INJ with 1 valves |
| Ar Range 0-250ppb LDL 0.5ppb | INJ/HC with 2 valves |
| H2 Range 0-250ppb LDL 0.5ppb | INJ with 1 valves |
| N2/H2 Range 0-250ppb LDL 0.5ppb | INJ with 1 valves |
| CO Range 0-250ppb LDL 0.5ppb | INJ with 1 valves |
| CO2 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CH4 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CO2/CH4 Range 0-250ppb LDL 0.5ppb | BF/HC with 2 valves |
| CO2/CH4/NMHC Range 0-250ppb LDL 0.5ppb | BF/HC/SEL with 3 valves |
| | |
| Chassis options | |
| Master Chassis | Max. 2 channels with 4 valves |
| PC+ Slave chassis | 2 BF/HC channels |
| Master +Slave1 Chassis | Max. 4 channels with 8 valves |
| | |
| Carrier Gas | Helium |
| | |
| | |
| Power | 115 VAC, 50-60 Hz |
| | 220 VAC, 50-60 Hz |
| | |
| Gas Connectors (to match accessories fittings) | 1/8" VCR |
| | |
| Serial port | RS-232 |
| | |
| | |
| Remote Support | VNC |
| | Net Support |
| | |
| Internal Dilution System | Not Required ( > 1ppm) |
| | Required ( One per Chassis) |
| | |
| | |
| | |
| | |
| | |
| SERVOPRO PureGas | Gas Purifier |
| | |
| 02005A1_01 | SERVOPRO PUREGAS, 1/8" COMP, 110V |
| 02005A1_02 | SERVOPRO PUREGAS, 1/8" COMP, 220V EU |
| 02005A1_03 | SERVOPRO PUREGAS, 1/8" COMP, 220V UK |
| 02005A1_04 | SERVOPRO PUREGAS, 1/8" VCR, 110V |
| 02005A1_05 | SERVOPRO PUREGAS, 1/8" VCR, 220V EU |
| 02005A1_06 | SERVOPRO PUREGAS, 1/8" VCR, 220V UK |
| | |
| | |
| SpectraScan Analyser | |
| | |
| 02400A1 | SpectraScan Analyser |
| | |
| Components | 1 to 3 Components |
| | 4 to 6 Components |
| | 7 to 8 Components |
| | |
| 04404A1 | Nitrogen Purity Analyser Base |
| | includes report software, SS liners, packaging |
| | |
| Trace (>10 ppm), Pack 1 | O2 Impurity - Enter range & LDL |
| | 0-10ppm ≤O2 range ≤ 0-100ppm LDL is 1.5% full scale |
| | H2 Impurity - Enter range & LDL |
| | 0-10ppm ≤H2 range ≤ 0-100ppm LDL is 1.5% full scale |
| | CH4 Impurity - Enter range & LDL |
| | 0-10ppm ≤CH4 range ≤ 0-100ppm LDL is 1.5% full scale |
| | |
| Trace (>10 ppm), Pack 2 | Same as Pack 1 + |
| | Ar Impurity - Enter range & LDL |
| | 0-10ppm ≤Ar range ≤ 0-100ppm LDL is 1.5% full scale |
| | |
| Trace (>10 ppm), Pack 3 | Same as Pack 2 + |
| | CO Impurity - Enter range & LDL |
| | 0-10ppm ≤CO range ≤ 0-100ppm LDL is 1.5% full scale |
| | |
| Trace (>10 ppm), Pack 4 | Same as Pack 3 + |
| | CO2 Impurity - Enter range & LDL |
| | 0-10ppm ≤CO2 range ≤ 0-100ppm LDL is 1.5% full scale |
| | |
| Trace Exact (<10 ppm), Pack 1 | O2 Impurity - Enter range & LDL |
| | 0-1ppm ≤O2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| Min Range 0-1 ppm | H2 Impurity - Enter range & LDL |
| | 0-1ppm ≤H2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | CH4 Impurity - Enter range & LDL |
| | 0-1ppm ≤CH4 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | |
| Trace Exact (<10 ppm), Pack 2 | Same as Pack 1 + |
| | Ar Impurity - Enter range & LDL |
| Min Range 0-1 ppm | 0-1ppm ≤Ar range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | |
| Trace Exact (<10 ppm), Pack 3 | Same as Pack 2 + |
| | CO Impurity - Enter range & LDL |
| Min Range 0-1 ppm | 0-1ppm ≤CO range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | |
| Trace Exact (<10 ppm), Pack 4 | Same as Pack 3 + |
| | CO2 Impurity - Enter range & LDL |
| Min Range 0-1 ppm | 0-1ppm ≤CO2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | |
| | |
| Carrier Gas | Argon |
| | Helium (if Argon impurity) |
| | |
| Power | 115 VAC, 50-60 Hz |
| | 220 VAC, 50-60 Hz |
| | |
| Gas Connectors (to match accessories fittings) | 1/8" Swagelok |
| | 1/8" VCR (if 0-1 ppm range) |
| | |
| Serial port | Not Required |
| | RS-232 |
| | |
| Remote Support | VNC |
| | Net Support |
| | |
| Dual Inlets (sample + span, with switching) | Not Required |
| | Required |
| | |
| Calibration using background gas | Not required |
| | Required |
| | |
| | |
| | |
| 04405A1 | Oxygen Purity Analyser Base |
| | includes report software, SS liners, packaging |
| | |
| ASU Process (>10 ppm), Pack 1 | CH4 Impurity - Enter range & LDL |
| | 0-10ppm ≤CH4 range ≤ 0-500ppm LDL is 1.5% full scale |
| | NMHC Impurity - Enter range & LDL |
| | 0-5ppm ≤CH4 range ≤ 0-200ppm LDL is 1.5% full scale Min.100ppb |
| | |
| Trace (>10 ppm), Pack 1 | N2 Impurity - Enter range & LDL |
| | 0-10ppm ≤N2 range ≤ 0-100ppm LDL is 1.5% full scale |
| | (with O2 trap in aux oven) |
| | |
| Trace (>10 ppm), Pack 2 | Same as Pack 1 + |
| | H2 Impurity - Enter range & LDL |
| | 0-10ppm ≤H2 range ≤ 0-100ppm LDL is 1.5% full scale |
| | CH4 Impurity - Enter range & LDL |
| | 0-10ppm ≤CH4 range ≤ 0-100ppm LDL is 1.5% full scale |
| | |
| Trace (>10 ppm), Pack 3 | Same as Pack 2 + |
| | CO2 Impurity - Enter range & LDL |
| | 0-10ppm ≤CO2 range ≤ 0-100ppm LDL is 1.5% full scale |
| | |
| Trace (>10 ppm), Pack 4 | Same as Pack 3 + |
| | CO Impurity - Enter range & LDL |
| | 0-10ppm ≤CO range ≤ 0-100ppm LDL is 1.5% full scale |
| | |
| Trace (>10 ppm), Pack 5 | Same as Pack 4 + |
| | Ar Impurity - Enter range & LDL |
| | 0-10ppm ≤Ar range ≤ 0-100ppm LDL is 1.5% full scale |
| | |
| Trace Exact (<10 ppm), Pack 1 | N2 Impurity - Enter range & LDL |
| | 0-1ppm ≤N2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| Min Range 0-1 ppm | (with O2 trap in aux oven) |
| | |
| Trace Exact (<10 ppm), Pack 2 | Same as Pack 1 + |
| Min Range 0-1 ppm | H2 Impurity - Enter range & LDL |
| | 0-1ppm ≤H2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | CH4 Impurity - Enter range & LDL |
| | 0-1ppm ≤CH4 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | |
| Trace Exact (<10 ppm), Pack 3 | Same as Pack 2 + |
| | CO2 Impurity - Enter range & LDL |
| Min Range 0-1 ppm | 0-1ppm ≤CO2 range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | |
| Trace Exact (<10 ppm), Pack 4 | Same as Pack 3 + |
| | CO Impurity - Enter range & LDL |
| Min Range 0-1 ppm | 0-1ppm ≤CO range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | |
| Trace Exact (<10 ppm), Pack 5 | Same as Pack 4 + |
| | Ar Impurity - Enter range & LDL |
| Min Range 0-1 ppm | 0-1ppm ≤Ar range < 0-10ppm LDL is 1.5% full scale,Min.50ppb |
| | |
| Carrier Gas | Argon |
| | Helium (if Argon impurity measured) |
| | |
| Power | 115 VAC, 50-60 Hz |
| | 220 VAC, 50-60 Hz |
| | |
| Gas Connectors (to match accessories fittings) | 1/8" Swagelok |
| | 1/8" VCR (if 0-1 ppm range) |
| | |
| Serial port | Not Required |
| | RS-232 |
| | |
| Remote Support | VNC |
| | Net Support |
| | |
| Dual Inlets (sample + span, with switching) | Not Required |
| | Required |
| | |
| Calibration using background gas | Not required |
| | Required |