Thứ Tư, 29 tháng 7, 2015

Servomex Vietnam | 2930B SERVOTOUGH LaserSP | 02930B1

Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong
D5 KDC Miếu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh

Contacs: Mai Văn Vinh
Tell : 0915.980.479        0162.999.888.7

Email :      vinhmv@pitesco.com
Website:   www.pitesvietnam.com                                       
                 www.sensor-encoder.com                   
                 www.hohner.vn


Servomex Vietnam 2930B SERVOTOUGH LaserSP 

  
2930B SERVOTOUGH LaserSP 
  
02930B1SERVOTOUGH LaserSP
CONFIGURATION 
 Single Path
AREA CLASSIFICATION 
 Safe Area
 ATEX  and IECEx Cat 3 Gas (Zone 2) Cat 2 Dust (Zone 21)
 ATEX Cat. 2G (Zone 1)
 CSA general purpose
 CSA Class 1, Division 2
  
MEASUREMENT 
Single Path monitorsMeasurement
  
 O2 SERVOTOUGH LaserSP Monitor (oxygen)
 HOT O2 SERVOTOUGH LaserSP Monitor (oxygen)
 CO SERVOTOUGH LaserSP Monitor, low level detection limit 0.3ppm (carbon monoxide)
 NH3 SERVOTOUGH LaserSP Monitor (ammonia)
  
MEASURING RANGE 
 Please state
MEASUREMENT UNITS 
 mg/m3
 ppm
 % vol
  
DUAL MEASUREMENT 
 Not Required
 Dual gas, add on temperature (for O2 and CO)
  
DUAL MEASURING RANGE 
 Please state
  
DUAL MEASUREMENT UNITS 
 mg/m3
 ppm
 % vol
 Celsius
  
 Gas Component 1
 Stream Comp 1 Normal Range
 Stream Comp 1 Low Range
 Stream Comp 1 High Range
 Process Dust (mg/m3)
 Process Flow (m3/h)
 Process Velocity (m/sec)
 Process Opacity (%)
 Stream Temperature (°C)
 Ambient Temperature (°C)
  
 Trans/Rec Cable 10m (5m supplied as standard)
 Trans/Rec Cable 15m (5m supplied as standard)
 Trans/Rec Cable 20m (5m supplied as standard)
 TU/RU Connecting Cable 5-20m (per metre). 5m supplied as standard.
  
 TU Optical Path Length L1 (mm)
 Stack Diameter L2 (mm)
 RU Optical Path Length L3 (mm)
  
PROCESS PRESSURE UNITS 
 mbar
 bar
  
PROCESS PRESSURE (bar) 
 Please specify
  
OPTICAL WINDOW PURGING 
 None (low dust)
 Instrument Air
 Fan
 N2 (low level O2)
 Steam
SUPPLY VOLTAGE 
 110Vac 50/60Hz
 220Vac 50/60Hz
 24Vdc
HIGH TEMPERATURE APPLICATIONS 
 High temp. O2/CO2/CO applications(>700C) RU Filter mounted/tested
 13606 High Temp O2 with Air Purge (>500C)
  
MOUNTING FLANGE 
 DN50/PN10 (SP Standard)
 DN80/PN10, pair
 ANSI 2"/150lbs, pair
 ANSI 3"/300lbs, pair
  
  
 ANSI 4" 150/300lbs, pair
 Other (Specify)
  
SPECIAL FLANGE O-RINGS21031 DN50 Flange 0-ring, 65.0x10.0, PTFE (Teflon)  Max 250C
 21033 DN50 Flange 0-ring, 65.0x10.0, FKM (Viton)  Max 200C
 21034 DN80 Flange 0-ring, 95.0x10.0, FKM (Viton)  Max 200C
TU MOUNTING 
 Indoor
 Outdoor
  
CALIBRATION CELL 
 Stainless Steel (316) For corrosive gases (except HF)
 Stainless Steel (316) For corrosive gases (except HF)
 Cal cell for O2 (Al) For non-corrosive gases
 Cal cell for HF (AI/PTFE)
MEASUREMENT CELL 
 Measurment Cell 150mm (316SS electro-polished) with sapphire window & DN50 Flange
 Measurment Cell 240mm (316SS electro-polished) with sapphire window & DN50 Flange
 Measurment Cell 50omm (316SS electro-polished) with sapphire window & DN50 Flange
 Measurment Cell 700mm (316SS electro-polished) with sapphire window & DN50 Flange
 Measurment Cell 1000mm (316SS electro-polished) with sapphire window & DN50 Flange
TRANSMISSION OUTPUT 
 Additional 4-20mA for Trans o/p
 Auxiliary board including one 4-20mA
 Second and third 4-20mA analogue output (13474 is required for this option)
ETHERNET OUTPUT 
 Ethernet Connection (without cable)
  
ADDITIONAL NETWORK CABLE 
 Network Cable 15m (including connectors) straight
 Network Cable 15m (including connectors)cross-over
TU/RU PURGING 
 None (Blanked)
 N2 Fittings (Low Level O2)
  
2nd PURGE PORT FITTING 
 Option for 2 purge fitting on each purge/alignment unit
HIGH PRESSURE WINDOW >5 BAR 
 High Pressure Window for O2 HP O2 measurement
  
ALIGNMENT TOOLS 
 Alignment jig w/target
 IR Card (not suitable for HCl, NO, Low conc CO, CO2)
  
  
PURGE GAS FILTRATION 
 Purge Gas Filter Unit
  
INTEGRATED SPAN CHECK 
 Span check (for non corrosive gases only) incl. switch box.  Check application feasability with Technical Centre before quoting.
 Fixed internal sealed cell (Laser tracking typically for "zero" type applications) Check application feasability with
Technical Centre before quoting.
 Span check with internal sealed cell. Check application feasability with Technical Centre before quoting.
  
2 YEARS SPARES KIT 
 2 years spares kit
  
CERTIFICATE OF ORIGIN 
 Certificate of origin (May be required for FAT by customer)
  
  
  
02930964AMeasurment Cell 150mm (316SS electro-polished) with sapphire window & DN50 Flange
02930964BMeasurment Cell 240mm (316SS electro-polished) with sapphire window & DN50 Flange
02930964CMeasurment Cell 50omm (316SS electro-polished) with sapphire window & DN50 Flange
02930964DMeasurment Cell 700mm (316SS electro-polished) with sapphire window & DN50 Flange
02930964EMeasurment Cell 1000mm (316SS electro-polished) with sapphire window & DN50 Flange
  
  
2940A SERVOTOUGH LaserCompact 
  
02940A1SERVOTOUGH LaserCompact
CONFIGURATION 
 Compact
AREA CLASSIFICATION 
 Safe Area
 Exn ATEX/IECEx Zone 2 Option
 CSA general purpose - Standard single path
 N. American CL 1 DIV 2
  
MEASUREMENT 
Compact monitorsMeasurement
  
 O2 LaserCompact Monitor
 CO LaserCompact Monitor % CO
 CO LaserCompact Monitor ppm CO
 CO2 LaserCompact Monitor % CO2
 CO2 LaserCompact Monitor ppm CO2
 NH3 LaserCompact Monitor
 HF LaserCompact Monitor
 HCl LaserCompact Monitor
 H2O LaserCompact Monitor ppm H2O
 H2O LaserCompact Monitor ppm H2O in HC
 H2S LaserCompact Monitor
 H2O LaserCompact Monitor % H2O
 CH4 LaserCompact Monitor (methane)
 HCN LaserCompact Monitor (hydrogen cyanide)
 C3H6 LaserCompact Monitor (propylene)
 C2H4O LaserCompact Monitor (ethylene oxide)
 CH2O LaserCompact Monitor (formaldehyde)
 N2O SERVOTOUGH LaserCompact Monitor (nitrous oxide)
 N2O SERVOTOUGH LaserCompact Monitor (ppm nitrous oxide)
 C2H2 ServoTough Laser Compact: Acetylene measurement
  
MEASURING RANGE 
 Please state
MEASUREMENT UNITS 
 mg/m3
 ppm
 % vol
  
DUAL MEASUREMENT 
 Not Required
 H2O dual gas Add-on
 CH4 Dual Gas Add-on
  
DUAL MEASURING RANGE 
 Please state
  
DUAL MEASUREMENT UNITS 
 mg/m3
 ppm
 % vol
 Celsius
  
  
 Gas Component 1
 Stream Comp 1 Normal Range
 Stream Comp 1 Low Range
 Stream Comp 1 High Range
 Process Dust (mg/m3)
 Process Flow (m3/h)
 Process Velocity (m/sec)
 Process Opacity (%)
 Stream Temperature (°C)
 Ambient Temperature (°C)
  
 Trans/Rec Cable 10m (5m supplied as standard)
 Trans/Rec Cable 15m (5m supplied as standard)
 Trans/Rec Cable 20m (5m supplied as standard)
 TU/RU Connecting Cable 5-20m (per metre). 5m supplied as standard.
  
 TU Optical Path Length L1 (mm)
 Stack Diameter L2 (mm)
 RU Optical Path Length L3 (mm)
  
PROCESS PRESSURE UNITS 
 mbar
 bar
  
PROCESS PRESSURE (bar) 
 Please specify
OPTICAL WINDOW PURGING 
 None (low dust)
 Instrument Air
  
  
 Fan
 N2 (low level O2)
 Steam
SUPPLY VOLTAGE 
 110Vac 50/60Hz
 220Vac 50/60Hz
SPECIAL FLANGE O-RINGS 
 DN 50 PTFE O-ring
 DN50 Viton O-ring
 DN80 Viton O-ring
HIGH TEMPERATURE APPLICATIONS 
 High temp. O2/CO2/CO applications(>700C) RU Filter mounted/tested
 High Temp O2 with Air Purge (>500C)
MOUNTING FLANGE 
 DN80/PN10 (DP Standard)
 ANSI 2"/150lbs
 ANSI 3"/150lbs
 ANSI 4"/150lbs
CALIBRATION CELL 
 Calibration Cell Stainless Steel (316)
 Calibration Cell Stainless Steel (316) For corrosive gases (except HF)
 Cal cell for O2 (Al)
MEASUREMENT CELL 
 Order measurement cell as separate item: See 02930964 measurement price list below.
 Cal cell for HF (Al/PTFE
TRANSMISSION OUTPUT 
 Addnl 4-20mA - Trans O/P
ETHERNET OUTPUT 
 Ethernet Connection (without cable)
CABLES 
 Trans/Rec Cable 10m (5m supplied as standard)
 Trans/Rec Cable 15m (5m supplied as standard)
 Trans/Rec Cable 20m (5m supplied as standard)
 Net Cable 15m Straight
2nd PURGE PORT FITTING 
 Option for 2 purge fitting on each purge/alignment unit
ALIGNMENT TOOLS 
 Alignment jig w/target
 IR Card
PURGE GAS FILTRATION 
 Purge Gas Filter Unit
  
  
  
  
2950A SERVOTOUGH LaserExact 
  
02950A1SERVOTOUGH LaserExact
CONFIGURATION 
 MultiPass
AREA CLASSIFICATION 
 Safe Area
 CSA General Purpose
 CSA Class 1 Div 2
 Ex n ATEX Cat 3
  
MEASUREMENT 
MultiPass monitorsMeasurement
  
 H2S LaserExact Monitor
 O2 LaserExact Monitor
 NH3 LaserExact Monitor
 HCL LaserExact Monitor
 HF LaserExact Monitor
 CO LaserExact Monitor
 CO2 LaserExact Monitor
 CO (hi sens) LaserExact Monitor
 H2O LaserExact Monitor
 HCN LaserExact Monitor
 CH4 LaserExact Monitor
 CO2 (hi sen) ST LaserExact Monitor
 C2H2 ST LaserExact Monitor
  
OPTIONS/ACCESSORIES 
 Addnl 4-20mA - Trans O/P
 Ethernet w/o cable